

This video shows an amplifier “Failing” an important performance test when measured with an out-of-spec instrument, yet it “Passes” once the spectrum analyzer is restored to warranted OEM specifications.ĭe-Mystifying Calibration Accreditation Webinar Out-of-Cal Instruments Cause “Bad” Pass/Fail Decisions Give us 3 minutes and we'll help you become an informed consumer of calibration services. ANSI/NCSL Z540.3-2006 requires that "the probability that incorrect acceptance decisions (false accept) will result from calibration tests shall not exceed 2% and shall be documented." This video explains "probability of false acceptance" in simple terms, then covers compliance methods, and finally, availability of Z540.3 calibration for Keysight Technologies instruments.ĭespite what you may hear, not all calibrations are equal. New contracts with Z540.3 "flow-down" requirements are probably a matter of time if you currently require Z540-1 calibrations.
#Fotonica significato how to
Is an "accredited cal" different from a calibration from an "accredited laboratory"? If two calibration laboratories are both accredited do they have the same quality? What is the risk to you if you order a calibration from a lab and some of the measurements are outside their published "scope-of-accreditation"? Unfortunately, accreditation is often confusing, but it doesn't have to be! This video de-mystifies accreditation, answers these questions, and provides you with a clear understanding on how to determine what you should look for in an accredited calibration lab.

This video simply covers the key deliverables needed to comply with ISO/IEC 17025, ILAC-G8, ILAC-P14, A540-1, and Z540.3, so you'll know what to look for in calibration reports from calibration labs claiming to comply with these standards. This list, also called a trace report, can help you determine if your critical measurements were calibrated.Įver wonder why calibration standards are written with such complex language? You are not alone. Although all calibration labs include the list of instruments used for the calibration of your test equipment, not all labs calibrate the critical performance tests that are important to the measurements you make. The importance of traceability depends on your relative need for low measurement uncertainty. Stated simply, traceability is the process of relating your measurement back to the most accurate standard used by a national metrology institute, such as NIST, NPL, PTB, etc. Step 2 is to answer "How accurate are those measurements?" This video explains how calibration measurement uncertainty is determined, and why it matters to you and for standards compliance. Step 1 of calibration is to measure actual instrument performance. Metrologists define "accuracy" using the term "measurement uncertainty". This video provides an overview of how automated procedures with external equipment ensure that your instrument performs to OEM specifications. But modern instruments don't use screwdrivers anymore. You may unknowingly be making measurements that are outside the manufacturer's specification! If the instrument you send in for calibration service is measured out-of-spec, then you need OEM adjustments to be performed. At the end of this video, you will know what to ask for, what to expect, and why, when you evaluate who to choose for instrument calibration service.Ĭalibration Adjustments. A video player and MP4/H.256 codec is required to play the files.ĭo you just assume good things will happen when you send your instrument in for calibration service? Sadly, they don't always.
#Fotonica significato mp4
On the business side, it means lower cost of ownership.ĭownload the videos by clicking on the MP4 link below and choosing the 'save as' option. On the technical side that means accurate measurement results. The Keysight Services videos highlight how calibration meets technical and business goals.
